Foil Scrim-Kraft Facing
Product application
Foil Scrim-Kraft Facing Suitable for a wide variety of applications, it can be used as insulation and vapor barrier layer for numerous insulation materials, with good aging resistance and corrosion resistance.Our facings are designed with proprietary flame retardant chemistry to meet demanding fire codes and standards.
Construction
Facing Composition | Description | FSK60A Value (Metric) | FSK50B Value (Metric) | FSK50AR Value (Metric) |
Foil | Aluminum | 7 micron | 7 micron | 7 micron |
Reinforcing | Fiberglass | 8 /100mm- MD | 8 /100mm- MD | 8 / 100mm - MD |
12 /100mm- XD | 8 /100mm- MD | 12 / 100mm - XD | ||
Adhesive | Polyethylene | -- | ||
Kraft | Natural | 60gsm | 50gsm | 50gsm |
Typical Physical Property
Physical Property | Test Method | FSK60A Value (Metric) | FSK50B Value (Metric) | FSK50AR Value (Metric) |
Basis Weight | Scale | 85 gsm | 85 gsm | 80 gsm |
Permeance | ASTM E96 | 5.75 ng/N.s | 5.75 ng/N.s | 5.75 ng/N.s |
Tensile Strength | ASTM D828 | 116 N/25mm- MD | 116 N/25mm- MD | 100 N/25mm- MD |
56 N/25mm- XD | 56 N/25mm- XD | 50 N/25mm - XD | ||
Burst Strength | ASTM D774 | 30 N/cm2 | 30 N/cm2 | 30 N/cm2 |
Temperature Resistance | ASTM C1263 -30 °C/+90 °C | Remains Flexible No Delamination | Remains Flexible No Delamination | Remains Flexible No Delamination |
Dimensional Stability | ASTM D1204 @150F(65C) | Less than 0.5% | Less than 0.5% | Less than 0.5% |
Emissivity | ASTM E408 | -- | -- | 0.03 |
Fire Rating | BS 476 | -- | -- | Class 0 |
Reflectivity of foil surface | BS 476 | 97% | 97% | -- |
Roll Width:1.0m,1.2m,1.25m;Roll length from60mup to2800M.
Remarks:
- 1. Above data are typicalresults and not the guaranteed performance.
- 2. Tolerance: Weight and Thickness: ±10%; Width: ±2mm; Length: ±0.5%.
- 3. The products should be stored at room temperature away from chemical, wetand heat source. Rolls should never be stored in direct contact with the groundor on concrete slabs.
- 4. Please do trial-application and makesure the product can serve the specific application before actually put it touse.